Leave Your Message

China RCDEQ-T Series Forced Oil Cooled Electromagnetic Iron Remover - Reliable Suppliers from Trusted Factory

Product Overview

,

Introducing a state-of-the-art iron removal solution, tailored for the rigorous needs of coal transportation ports, large thermal power plants, coal mines, and other industrial environments in China. Our innovative iron remover, designed by leading suppliers, is strategically engineered to be suspended above extensive conveyor belts. This advanced system effectively removes small iron particles from coal, significantly enhancing material quality and ensuring optimal performance. As a trusted factory in the industry, we are committed to providing top-tier solutions for all your iron removal needs.

    Main features

    Forced Oil Circulation Cooling

    Equipped with forced oil circulation cooling technology, ensuring extremely low temperature rise (≤40℃). It guarantees safe and reliable operation in harsh environments with severe dust, moisture, and salt spray corrosion.

    Mature Transformer Technology

    Utilizes large and medium-sized transformers with forced oil circulation cooling technology. This mature and widely adopted method ensures a safe, stable, and highly reliable performance in demanding industrial settings.

    High Iron Removal Efficiency

    Boasts a short magnetic circuit, minimal magnetic loss, a large magnetic field gradient, and a high iron removal rate. This ensures the efficient and effective extraction of iron particles from conveyed materials.

    Practical & Lightweight Design

    Designed with practicality in mind. Its lightweight structure simplifies installation and maintenance, while the engineered oil circuit and compact cooler enhance heat dissipation efficiency.

    Sealed Protection

    The excitation coil is fully immersed in sealed transformer oil, offering excellent dust-proof, moisture-proof, and anti-corrosion properties to withstand the most challenging industrial environments.

    Three-Dimensional Winding

    Constructed with a three-dimensional winding that offers a large heat dissipation area, low temperature rise (≤40℃), and an extended coil service life, reducing overall maintenance costs.

    RCDEQ series forced oil-cooled electromagnetic iron remover represents a significant advancement in iron removal technology for industrial applications. Its innovative features, including forced oil circulation cooling technology, efficient magnetic circuit design, and practical construction, make it a reliable and effective solution for addressing the high requirements of iron removal in demanding industrial settings.

    Main technical parameters

    RCDEJ series forced oil cooled electromagnetic iron removerblt
    NO. Mode conveyor belt Suspension Magnetic Belt Existing Condenser Weight Appearance size
    width height intensity speed power power (kg) (mm)
    (mm) (h=mm) (≥mt) (m/s) (≤kw) (≤kw)    
    1 RCDEQ-10 T1 1000 300 90 ≤5.8 6.5 0.25 3450 2960×1620×1480
    T2 120 9.5 0.25 3820 2960×1620×1520
    T3 150 15 0.25 4500 3000×1620×1550
    2 RCDEQ-12 T1 1200 350 90 9 0.25 3850 3250×1770×1520
    T2 120 14 0.25 4620 3350×1770×1590
    T3 150 20 0.25 6600 3520×1770×1590
    3 RCDEQ-14 T1 1400 400 90 14 0.25 4650 3350×1750×1550
    T2 120 20 0.25 6780 3520×1860×1590
    T3 150 29 0.25 8560 3630×1860×1620
    4 RCDEQ-16 T1 1600 450 90 18 0.25 5760 3520×1850×1590
    T2 120 28 0.25 8920 3750×2250×1620
    T3 150 32 0.25 10200 3950×2250×1630
    T4 175 52 0.75 12300 4120×2470×1750
    T5 200 70 0.75 14375 4170×24700×1750
    T6 225 85 1.1 16730 4230×24900×1800
    T7 250 104 0.55×2 18250 4350×25300×1860
    5 RCDEQ-18 T1 1800 500 90 26 0.75 8800 3950×2250×1630
    T2 120 32 0.75 10500 3950×2450×1650
    T3 150 40 0.75 12500 4000×2450×1670
    T4 175 56 0.75 18560 4240×2500×1800
    T5 200 75 0.75 20754 4300×2520×1850
    T6 225 90 1.1 22500 4300×2580×1900
    T7 250 107 0.55×2 23500 4400×2650×1950
    6 RCDEQ-20 T1 2000 550 90 30 0.75 11650 3950×2450×1650
    T2 120 39 0.75 13500 4100×2680×1670
    T3 150 41 0.75 15200 4620×2680×1670
    T4 175 70 0.55×2 24580 4400×2680×1830
    T5 200 83 0.55×2 25435 4470×2700×1900
    T6 225 104 0.55×2 27890 4520×2730×2150
    T7 250 125 0.55×2 29500 4600×2800×2250
    7 RCDEQ-22 T1 2200 600 90 39 0.75 13200 4100×2680×1670
    T2 120 42 0.75 16500 4260×2750×1690
    T3 150 45 0.75 17260 4500×2750×1690
    T4 175 100 0.55×2 28750 4650×2850×2200
    T5 200 121 0.55×2 30445 4700×2900×2300
    T6 225 153 0.55×2 32270 4780×2900×2300
    T7 250 176 0.55×2 34100 4830×2950×2370
    8 RCDEQ-24 T1 2400 650 90 40 0.75 16800 4260×2750×1690
    T2 120 46 0.75 18500 4500×2750×1690
    T3 150 54 0.75 22000 4800×2950×1720
    T4 175 120 0.55×2 34750 4600×2850×2100
    T5 200 150 0.55×2 37680 4700×2950×2280
    T6 225 180 0.55×2 40585 4850×3000×2430
    T7 250 200 1.1×2 44500 4950×3100×2560

    Frequently Asked Questions

    What is the advantage of the forced oil circulation cooling technology?

    This technology ensures an extremely low temperature rise (≤40℃), which maintains a safe and reliable operation even in harsh environments exposed to severe dust, moisture, and salt spray corrosion.

    How does the RCDEQ series protect against environmental damage?

    The excitation coil of the RCDEQ series is completely immersed in sealed transformer oil, providing excellent dust-proof, moisture-proof, and anti-corrosion capabilities.

    What features contribute to its high iron removal rate?

    The iron remover is designed with a short magnetic circuit, which minimizes magnetic loss, and provides a large magnetic field gradient to ensure a high and efficient iron removal rate.

    Is the equipment easy to install and maintain?

    Yes, the RCDEQ series iron remover features a lightweight design with a meticulously engineered oil circuit and compact cooler, making installation and maintenance highly manageable.

    How does the three-dimensional winding benefit the coil's service life?

    The three-dimensional winding construction offers a large heat dissipation area. This keeps the temperature rise low (≤40℃) and significantly extends the coil service life, reducing overall maintenance requirements.

    What makes the cooling technology in this series reliable?

    It utilizes large and medium-sized transformers with forced oil circulation cooling, a widely adopted and mature cooling technology globally, ensuring consistent safety and reliability for industrial operators.